Watchguard ACLOC104: a fail-secure electric door strike in chrome plated steel, running on 12 VDC at 400 mA.
- ✓12 VDC at 400 mA
- ✓Fail-secure: locked with no power
- ✓9.5 mm door latch, 9.6 mm keeper depth
- ✓Chrome plated steel
- ✓Overall 144.5 × 36.4 × 25 mm
Description

A chrome finish strike.
12 VDC, fail-secure.
The Watchguard ACLOC104 is a chrome plated steel electric door strike for access control. It runs on 12 VDC at 400 mA and is fail-secure, so the door stays locked if the power goes off.
In one sentence: the Watchguard ACLOC104 is a fail-secure electric door strike in chrome plated steel, drawing 400 mA at 12 VDC, measuring 144.5 × 36.4 × 25 mm, for a 9.5 mm door latch with a 9.6 mm keeper depth.
Door strike only. The reader, power supply and cable are separate.
This listing is one ACLOC104 strike. It needs something to switch it (a reader, controller or intercom relay), a 12 VDC supply and cable to the door frame.
- ACLOC104 door strike
- An access control reader, controller or intercom with a lock relay
- A 12 VDC supply able to deliver 400 mA for the strike
- Two-core cable from the controller to the frame
- Fixing screws to suit your frame (confirm what is supplied with us)
- An exit button if people leave through the door
The same simple strike, in chrome.
The ACLOC104 has the same electrics as Watchguard's ACLOC100 and ACLOC101: 12 VDC at 400 mA, fail-secure, for a 9.5 mm latch. The difference is the chrome plated steel finish. With no power the door stays locked; when the reader, intercom or exit button switches 12 VDC to it, the keeper is free and the latch can pass.

Keeper
9.5 mm latch, 9.6 mm keeper depth.
The keeper releases when the strike is powered so the door's latch can pass. Watchguard rates it for a 9.5 mm door latch with a 9.6 mm keeper depth.

Fixing
Two fixing holes at each end.
The chrome plated plate extends past the strike body with two fixing holes at each end. Watchguard gives the overall size as 144.5 × 36.4 × 25 mm.
How it goes in
From frame to first swipe.
01
Check the fit
Measure the frame and the door's latch against the strike's 144.5 × 36.4 × 25 mm size and 9.5 mm latch rating, and confirm the mounting with us before cutting anything.
02
Run the cable
Run two-core cable from the reader, controller or intercom relay to the strike position.
03
Wire the power
Connect the 12 VDC lock output to the strike.
04
Fix and test
Screw the strike in line with the latch, check the door stays locked, then release it from the reader or exit button.
At a glance
ACLOC104
Show specs
Type
Electric door strike; Watchguard's 2023 datasheet lists it as surface mount
Power
12 VDC at 400 mA
Lock mode
Fail-secure (locked with no power)
Lock status sensor
No
Door latch
9.5 mm
Keeper depth
9.6 mm
Construction
Chrome plated steel
Overall size
144.5 × 36.4 × 25 mm
Faceplate
Listed as 175 × 29 × 3 mm, longer than the overall size; confirm with us before cutting the frame
Holding force
Approx. 272 kg, Watchguard's figure for its door strike range
Pair it with
What switches and powers it
Reader
Watchguard ACRDR100 reader
A standalone IP55 card reader made to drive electric locks directly, for fail-safe or fail-secure locks. It runs on 12 VDC.
Intercom
Akuvox E12S video doorbell
Its lock relay switches the strike's power supply, so visitors can be let in from the app or a card at the door.
Exit
Watchguard ACDSW100 exit button
A heavy duty release button with NO, NC and COM contacts for the inside of the door.
Power
PS5000SM 12 VDC 5 A supply
A 12 VDC switched-mode supply with a 2.1 mm plug, with headroom for a reader plus the strike's 400 mA.
Where it is used
Where it is used
Chrome hardware doors
Matches chrome handles and fittings on an office or shop door.
Office entries
Card or PIN entry on a staff door, released by the reader.
Shop back doors
Fail-secure, so the door stays locked through a power cut.
Apartment entries
Released from an intercom relay when a visitor is let in.
Store rooms
Keep stock and equipment rooms to staff with a card.
Small business upgrades
Replace a key-only door with card entry on a 12 V reader.
ACLOC104 or ACLOC100
| ACLOC104 (this strike) | ACLOC100 | |
|---|---|---|
| Type | Surface mount (2023 datasheet) | Mortise mount |
| Power | 12 VDC at 400 mA | 12 VDC at 400 mA |
| Lock mode | Fail-secure | Fail-secure |
| Lock status sensor | No | No |
| Door latch | 9.5 mm | 9.5 mm |
| Keeper depth | 9.6 mm | 9.6 mm |
| Construction | Chrome plated steel | Steel |
| Overall size | 144.5 × 36.4 × 25 mm | 160 × 25 × 30.8 mm |
Both are on Watchguard's electronic door strikes datasheet (March 2023).
Common questions
What voltage does the ACLOC104 need?
12 VDC. Watchguard rates it at 400 mA, so the reader's lock output or the power supply must be able to deliver that.
Is it fail-secure or fail-safe?
Fail-secure only. It stays locked with no power and releases when 12 VDC is applied. For a strike that can be set either way, see the ACLOC102 or ACLOC105.
Is it mortise or surface mount?
Watchguard's current datasheet and product page list it as surface mount; an older 2017 brochure called it a mortise strike. Send us a photo of your frame and we will confirm the fit before you order.
What size is it?
Watchguard gives the overall size as 144.5 × 36.4 × 25 mm. The datasheet's faceplate figure of 175 × 29 × 3 mm is longer than that, so confirm the dimensions with us before cutting the frame.
What latch does it suit?
A 9.5 mm door latch. The keeper depth is 9.6 mm.
What is it made of?
Chrome plated steel.
Does it have a lock or door sensor?
No. For lock and door monitoring choose the ACLOC102 or ACLOC105.
How is it different from the ACLOC100?
The electrics are the same: 12 VDC at 400 mA, fail-secure, 9.5 mm latch and 9.6 mm keeper depth. The ACLOC104 is chrome plated; the ACLOC100 is a plain steel mortise strike with a 160 × 25 mm faceplate.
Will it work with a standalone reader?
Yes. Readers such as the Watchguard ACRDR100 drive the lock output directly and work with fail-secure locks. Check the lock output can supply 400 mA at 12 V.
Can an intercom open it?
Yes, through the intercom's lock relay switching the strike's 12 VDC supply, as on the Akuvox E12S.
What comes in the box?
The ACLOC104 strike. Watchguard doesn't list the other contents, so confirm the fixings with us if you need them.
Who should install it?
A security or access control installer. Fitting access control for others needs a security licence in most states, and concealed cabling should be run by a registered cabler.
Supported by InFront Technologies.
Need help checking the fit or matching the strike to your reader, intercom or power supply? Call 1300 736 970 or email [email protected]. The datasheet is on the Attachments tab.
Installation and safety
Low voltage only. 12 VDC. Never connect the strike to mains.
Exit doors. A fail-secure strike stays locked when power fails. On a door that is an exit path, check the building code and fire rules with a licensed installer first.
Licensing and cabling. Installing access control for others needs a security licence in most Australian states. Concealed cabling should be installed by a registered cabler.
What it does not do. No fail-safe mode, no lock or door sensor, and no power supply included. Watchguard publishes no weather rating, so fit it to a sheltered door.
Figures. From Watchguard's electronic door strikes datasheet (March 2023). Watchguard publishes no installation sheet or drawing for this model.
- Construction
- Chrome-plated steel
- Door Latch
- 9.5mm
- Faceplate Dimensions
- 175 x 29 x 3mm
- Keeper Depth
- 9.6 mm
- Lock Configuration
- Fail secure
- Lock Status Sensor
- No
- Overall Dimensions
- 144.5 x 36.4 x 25mm
- Power input
- 12VDC at 400mA
- Type
- Surface Mount